Openai/693c9f31-ecc0-8002-b134-64bcac79dd59
This conversation was exported from ChatGPT[1]
gpt-5-1 edit
User: How to program this edit
How to program this
Assistant: You’re looking at a Honeywell W7751 / XL50-series style Building Manager keypad often used with Excel/Delta/BMS panels. edit
You’re looking at a Honeywell W7751 / XL50-series style Building Manager keypad (often used with Excel/Delta/BMS panels). These older Honeywell front-end controllers all program the same way — through MENU → REVIEW/PROGRAM → change values → SAVE. Here’s the clear step-by-step process to read and program it using the keys shown in your picture.
✅ HOW TO PROGRAM THIS HONEYwell CONTROLLER edit
BUTTON IDENTIFICATION (what the keys do) edit
- MENU → Access programming menus
- NEXT / PREV (Up/Down arrows) → Move between menu items
- TAP (Left/Right) → Move between items on a line
- + / – → Change values (setpoints, times, etc.)
- FAST → Speeds up +/– changes
- PROGRAM → Enter programming mode
- RUN → Return to normal operation
- REVIEW → Look at all parameter values without changing
- BYPASS → Temporary override (occupied mode, etc.)
🔧 ENTER PROGRAM MODE edit
- Press PROGRAM (sometimes asks for a code—usually 0000 or not required on older models).
- Screen will show the first editable item.
📋 NAVIGATE THROUGH PARAMETERS edit
Use these keys:
- MENU → cycle through categories (Schedules, Setpoints, Outputs, Inputs, Limits, etc.)
- NEXT / PREV → move between points within a category
- TAP (side arrows) → move across options on one line
✏️ CHANGE A VALUE edit
- Navigate to the parameter (example: OCC SCHEDULE, COOL SETPOINT, HEAT SETPOINT, FAN MODE).
- Use + / – to change the value.
- Hold FAST while pressing +/– if you need large changes.
- Changes save automatically when you exit the point.
🕑 TO PROGRAM A SCHEDULE edit
- Press PROGRAM
- Press MENU until you see SCHED / OCC / TIME
- Use NEXT to choose the day (MON, TUE… or ALL)
- Use TAP → to move to the start time
- Use + / – to change the time
- Tap again to change stop time
- Repeat for all days
- Press RUN to exit
🌡️ TO CHANGE SETPOINTS edit
- PROGRAM
- MENU → SETPOINTS
- NEXT → choose HEAT, COOL, DAT LIMIT, etc.
- Adjust with +/–
- RUN to exit
⚠️ TO VIEW ALARMS edit
- Press REVIEW
- Use NEXT/PREV
- To clear an alarm, many of these require: - Fix the issue - Then press CLEAR
🚀 If you want, I can walk you through the exact programming for: edit
✔ Schedules ✔ Heating/cooling setpoints ✔ Occupancy override ✔ Resetting alarms ✔ Changing time/date ✔ Reviewing IO points
Just tell me what you need to program on this specific unit and I’ll give exact steps for that screen.
References edit
- ↑ "How to program Honeywell". ChatGPT. Retrieved 2025-12-13.